CaseReport1
CaseReport1
CaseReport1
ReportHistory
Exam
Prior Study
Findings & Impressions
Findings:
First, an image was taken with a single sip of barium to observe for tracheal aspiration. There was no aspiration.
Next, the patient drank 240cc of barium over 1 minute.
A chest film obtained at 1 minute showed a standing column of barium measuring 10.2 x 5.2 cm.
A 5-minute chest film was obtaining showing the column, which measures measures 19 x 4.3 cm.
A 10-minute chest film was obtaining showing the column measures 16.1 x 3.7 cm.
Impression:
Achalasia with a bird beak configuration of the esophagus.
Recommendations:
For your training purposes, recommendations are not included in this report.